My first thought - I'll repair them. As it turned out, they were for frequency/power range I had no interest whatsoever. So what one can do with a damaged Bird 43 slugs besides repair? A few things actually - it makes nice dummy slug for the Thruline section, it can be reworked into a RF sampler or just keep them for parts.
The original aluminum dummy slug could actually be improved on - it has a small design flaw IMHO - when inserted, it keeps the contact finger of the Thruline section pressed and under tension. This might lead to metal fatigue and eventually the contact finger could loose its spring action, causing poor electrical connection with the slug. Once, I saw a third party "dummy slug" where this issue was addressed with a shallow groove allowing the contact finger to rest. The normal Bird element already has two small lateral indentations on each side where the contact points are protruding.
First I "gutted" the slug, completely disassembling it and removing everything from inside including the internal contact plate. This was simple enough and left room for the contact finger of the Thruline section to rest without pressing onto anything. But why stop there? How about a hygroscopic dummy slug to absorb trapped moisture inside and to keep the Thruline cavity nice and dry?

Silica-gel is very easy to find - people normally discard the Silica-gel bags after they buy a pair of new leather shoes or a hard drive - I collect the little Silica-gel bags in a jar and re-use them.
Re-cycling Silica-gel is also easy - the Silica-gel needs to be "baked" for about 2 hrs in a toaster oven on "high" (250 - 300 F). This process will evaporate the moisture absorbed by the beads and the batch will be as good as new, ready to absorb more moisture again after it cools down.
Update: Another idea for enhancing the functionality of the "dummy slug" even further - small piece of felt/cloth/foam can be attached inside each contact bed of the slug. Then, (optional) a drop of Deoxit D5 solution can be used to moist this "cleaning pad". Each time when the slug is inserted or removed, it will wipe clean the contact finger.
In addition, instead of using only silica-gel beads, the dummy slug could be filled with a mixture of silica-gel and activated carbon. (another option, if moisture is not an issue, is to replace the silica-gel entirely with activated carbon). The activated carbon will absorb any sulfuric gasses in the air (like hydrogen sulfide) - sulfur is the main cause for the black tarnish on silver/silver-plated surfaces (the Truline cavity is silver-plated).